TM66E Modular 3:3 UPS Series
10 kVA to 1.2 MW
The ATENCO TM66E modular three-phase UPS series covers 10 kVA to 1.2 MW across four transformer-less online double-conversion platforms tailored to project scale: TM66E Compact Modular 30–75 kVA with built-in hot-swappable VRLA battery modules, TM66E Modular 10–150 kVA with 10–30 kVA hot-swappable power modules and external battery system, TM66E Modular 40–600 kVA with 40 / 50 / 60 kVA modules and VRLA / lithium battery support, and TM66E Large Modular 400 kVA to 1.2 MW with 100 kVA modules, HECO mode and lifecycle management. All platforms provide output PF 1.0, N+X redundancy and LBS synchronization by configuration.
Four TM66E Modular Three-Phase UPS Platforms
TM66E is organized into four transformer-less modular three-phase UPS platforms covering 10 kVA to 1.2 MW. Each platform is differentiated by cabinet architecture, power-module size, battery configuration, charger capacity, efficiency mode and parallel design, so the correct TM66E system can be matched to project capacity, redundancy plan, footprint and energy-saving target.
Modular 3-Phase UPS 30–75 kVA
Compact modular UPS with built-in hot-swappable VRLA battery modules for smaller critical-power projects.
- Output PF 1.0, online double-conversion VFI
- 3-level IGBT, up to 95.8% AC-mode efficiency
- Built-in hot-swappable VRLA battery modules
- Up to 6 internal battery groups by configuration
- 7” touchscreen + SNMP / RS-232 / RS-485 / EPO / LBS
Modular 3-Phase UPS 10–150 kVA
Rack-cabinet modular UPS with 10–30 kVA modules and external VRLA battery system.
- Output PF 1.0, online double-conversion VFI
- 10–30 kVA hot-swappable power modules
- 19” rack-cabinet architecture with external battery system
- 3-level IGBT and dual DSP control
- Parallel N+X up to 8 cabinets with LBS sync
Modular 3-Phase UPS 40–600 kVA
Medium-to-large modular UPS with VRLA / lithium battery support.
- Output PF 1.0, online double-conversion VFI
- 40 / 50 / 60 kVA hot-swappable power modules
- VRLA / lithium battery systems with 360–600 Vdc bus
- Charger up to 20A by model and configuration
- ECO / HECO modes up to 99%; N+X parallel up to 6 units
Modular 3-Phase UPS 400 kVA to 1.2 MW
High-capacity modular UPS with 100 kVA power modules for large scalable projects.
- Output PF 1.0, online VFI up to 97% AC-mode efficiency
- Built from 100 kVA hot-swappable power modules
- VRLA / lithium battery systems with 360–600 Vdc bus
- Charger up to 100A by model
- Parallel by model group: up to 6 units on 400–600 kVA, up to 4 units on 800–1200 kVA
ATENCO Three-Phase UPS Comparison Table
Compare ATENCO 3:1, 3:3, rack-mounted, transformer-based and modular online UPS systems by capacity, phase architecture, power factor, redundancy, battery configuration and application.
| Series | Architecture | Capacity | Phase | PF | Best For | Redundancy / Runtime | Efficiency | |
|---|---|---|---|---|---|---|---|---|
![]() |
3:1 online tower UPS | 10–20 kVA | 3:1 | 1.0 | Three-phase input sites with single-phase critical loads | External battery runtime by configuration | Up to 94% | Details → |
![]() |
3:1 rack/tower online UPS | 6–10 kVA | 3:1 | 1.0 | Rack-based telecom, IT and control-room loads | External / hot-swap battery options by model | Up to 93.5% | Details → |
![]() |
3:3 online tower UPS | 10–40 kVA | 3:3 | 1.0 | Small / medium 3-phase data center, facility and industrial loads | Parallel redundancy and external battery runtime by configuration | Up to 94.5% | Details → |
![]() |
3:3 standalone online UPS, 3-Level IGBT | 50–200 kVA | 3:3 | 1.0 | Medium / large data center, healthcare, telecom and industrial loads | Parallel up to 8 units and LBS by configuration; VRLA / lithium battery support by project | Up to 95.5% | Details → |
![]() |
3:3 rack-mounted online UPS | 10–50 kVA | 3:3 | 1.0 | Edge data centers, server racks and compact 3-phase IT power | Parallel / LBS options by model and configuration | Up to 95.5% | Details → |
![]() |
Four modular online UPS platforms | 10 kVA to 1.2 MW | 3:3 | 1.0 | Scalable data centers, telecom, industrial and modular critical-power projects | Hot-swappable modules, N+X redundancy, LBS sync and battery systems by platform | Up to 97%, platform/model-dependent | Details → |
![]() |
Transformer-based online UPS | 10–800 kVA | 3:3 | 0.9 | Galvanic isolation, neutral re-derivation and infrastructure projects | Parallel / LBS / external VRLA battery and generator-compatible design by project | Up to 94% | Details → |
30+ Years
UPS industry experience
50+ Countries
Distributor network worldwide
0 ms Online Transfer
Zero-transfer online double-conversion
CE / IEC 62040
Safety & EMC standards by series
TM66E Modular UPS FAQ
Answers about the TM66E modular three-phase UPS series, four-platform architecture, N+X redundancy, battery options, data-center suitability and generator compatibility.
What is the TM66E modular three-phase UPS series?
What TM66E platform should I choose?
Does TM66E support N+X redundancy?
Does TM66E support lithium batteries?
What is the difference between TM66E 40–600 kVA and 400–1200 kVA?
Is TM66E suitable for data centers?
Does TM66E support generator operation?
What battery options does TM66E support?
Are TM66E modular UPS certified for international projects?
Size the Right TM66E Modular UPS
Platform for Your Project
Share your load list, single-line diagram, redundancy plan, site voltage, backup-time target, battery requirement, installation space and monitoring requirements. ATENCO engineers will recommend the right TM66E platform – Compact Modular 30–75 kVA, Modular 10–150 kVA, Modular 40–600 kVA or Large Modular 400 kVA to 1.2 MW – with the correct power-module count, battery system, energy-saving mode options, parallel configuration and LBS design for your data center or critical-power project.
Send Project Requirements
Share your single-line diagram or load list, target backup time, redundancy plan (N, N+1, N+X), site voltage, generator details, ambient conditions, battery requirement, installation constraints and monitoring preferences such as SNMP, RS-485, BMS, dry contact, EPO or LBS.
Receive TM66E Platform Selection & Sizing
ATENCO engineers respond with the recommended TM66E platform, power-module configuration, cabinet layout, battery system, redundancy / parallel topology, LBS design, monitoring accessories and energy-saving mode options matched to your project.