TM33E SERIES

TM33E Three-Phase Tower UPS 10–40 kVA

TM33E is a transformer-less online double-conversion VFI three-phase tower UPS for data centers, industrial automation, telecom, healthcare facility IT and critical infrastructure projects. It accepts three-phase input and delivers protected three-phase output, with IGBT topology, full DSP control, output PF 1.0, 0 ms AC-to-battery transfer, wide input tolerance, generator-compatible input frequency, 7-inch TFT touchscreen and parallel operation up to 4 units by configuration. Available in 10 / 15 / 20 / 30 / 40 kVA models with internal-battery or external-battery configurations by model.

3-Phase In / 3-Phase Out PF 1.0 Output 10–40 kVA Parallel up to 4 Units 7″ TFT Touchscreen

Engineered for 3:3 Mission-Critical Power

Transformer-less online double-conversion three-phase UPS architecture for data centers, industrial automation, healthcare facility IT, telecom and critical infrastructure projects requiring protected three-phase output.

3-Phase In / 3-Phase Out (3:3)

Accepts 380 / 400 / 415 Vac three-phase input (3Ph+N+PE) and delivers protected 380 / 400 / 415 Vac three-phase output with ±1% regulation for data center IT, industrial automation, telecom, healthcare facility IT and critical infrastructure loads.

Online Double-Conversion VFI

Transformer-less online UPS topology with IGBT rectifier, IGBT inverter and full DSP control provides pure sine wave output and 0 ms AC-to-battery transfer for sensitive three-phase critical loads. Automatic bypass protection operates according to system condition.

PF 1.0 Output / Up to 94.5% Efficiency

Output PF 1.0 (kW = kVA) provides full usable kW capacity. Online efficiency reaches up to 94.5% on selected models, while input PF ≥0.99 and input THDi ≤3% help reduce upstream electrical stress.

Wide Input & Generator Compatibility

Wide input tolerance supports unstable utility supply and generator-backed sites: 208–478 Vac for 10–30 kVA models and 323–478 Vac for 40 kVA. Auto-sensing input frequency supports 45–55 Hz / 54–66 Hz operation by configuration.

Parallel up to 4 Units

Up to 4 TM33E units can be configured in parallel for capacity expansion or N+X redundancy, subject to model configuration and project design.

7″ TFT Touchscreen / Dual Intelligent Slots

7-inch TFT touchscreen HMI provides on-unit monitoring and configuration. Dual intelligent slots support TM550 SNMP and / or relay card options for remote monitoring, NMS / BMS integration and dry-contact signalling by configuration.

Expand Your System

Accessories for TM33E runtime extension, VRLA battery cabinets, remote monitoring and parallel redundancy – available by configuration.

ATENCO external TC-series VRLA battery cabinet for TM33E 10-40 kVA UPS long-runtime configurations

External Battery Cabinet

External TC-series VRLA battery cabinets support long-runtime TM33E configurations. Cabinet model, battery quantity and DC bus voltage are selected according to UPS capacity, load level, runtime target and project design.

ATENCO VRLA lead-acid maintenance-free battery string for TM33E internal or external configuration

VRLA Battery System

VRLA battery strings are selected according to TM33E capacity, DC bus configuration, load level and target backup time. Use batteries of the same brand, type, capacity and production batch for consistent string performance.

ATENCO TM550 SNMP network management card for TM33E dual intelligent slot

TM550 SNMP Card

Optional TM550 SNMP network card enables remote UPS monitoring, web access, event alerts and NMS / BMS integration. Dual intelligent slots support TM550 SNMP and / or relay card options by configuration.

ATENCO parallel cable and configuration kit for connecting up to 4 TM33E UPS units in N+X redundancy

Parallel Kit

Parallel cable / kit supports connecting up to 4 TM33E units for N+X redundancy or capacity expansion. Parallel cabling and configuration must follow the installation procedure.

Technical Details

Complete specifications for the TM33E 10–40 kVA three-phase tower UPS series.

Specification10 kVA15 kVA20 kVA30 kVA40 kVA
Full NameTM33E Three-Phase Tower Online UPS
TopologyOnline Double-Conversion (VFI), IGBT, DSP Control
Phase3P–3P (Three Phase In / Three Phase Out)
Form FactorTower
Capacity10 kVA / 10kW15 kVA / 15kW20 kVA / 20kW30 kVA / 30kW40 kVA / 40kW
Output Power Factor1.0 (kW = kVA)
Display7” Touchscreen TFT HMI
Operating ModesNormal (Online), ECO, Bypass, Battery, Maintenance
ParallelUp to 4 units (N+X redundancy, optional parallel kit)
Generator CompatibleYes
StandardsCE; IEC / EN 62040-1; IEC / EN 62040-2 (EMC); LVD by series
Specification10 kVA15 kVA20 kVA30 kVA40 kVA
Nominal Input Voltage380 / 400 / 415 Vac (3Ph + N + PE)
Input Voltage Range208–478 Vac323–478 Vac
Input Derating305–478 Vac full load; 208–304 Vac derated operation323–478 Vac operating range
Input PF≥0.99
Input THDi≤3% at 100% non-linear load
Input Frequency45–55 Hz / 54–66 Hz auto-sensing
Output Voltage380 / 400 / 415 Vac (3Ph + N + PE), ±1% regulation
Output PF1.0 (kW = kVA)
Output THDv≤2% linear / ≤5% non-linear
Output FrequencySynced to input in line mode; 50 / 60 Hz ±0.1 Hz in battery mode
Transfer Time0 ms (AC-to-Battery); automatic bypass protection by operating condition
Crest Factor3:1
Dynamic Voltage Transient≤±5%
Efficiency, AC Mode≥93.5%≥94.5%≥94.5%≥93.5%≥93.5%
Efficiency, ECO ModeAvailable for energy saving in stable utility conditions by model / configuration
Bypass Breaker20 A32 A40 A63 A100 A
SpecificationDetails
Battery Type12 V VRLA lead-acid maintenance-free
Battery ConfigurationInternal or external battery configuration by model
Internal Battery ModelsS models with internal battery compartment by configuration
Long-Run ModelsL models use external battery cabinets
DC Bus VoltageConfigured according to UPS capacity and battery design
Charger CurrentModel-dependent; selected according to battery capacity and project sizing
External Battery CabinetsTC-series external VRLA battery cabinets by project configuration
Battery RuntimeSized according to load, battery capacity and target backup time
Battery Life3–5 years typical at 25 °C; actual life depends on ambient temperature, cycling, discharge depth and maintenance conditions

For exact internal-battery counts, DC bus values, charger currents and external cabinet specifications, refer to the TM33E 10–40 kVA datasheet and the External Battery Cabinet Manual in the Downloads section, or contact ATENCO engineers for project sizing.

Physical – S Model / Internal Battery Configuration

Specification10 kVA15 kVA20 kVA30 kVA40 kVA
Form FactorTower
Dimensions (W×D×H)250×868×900mm
Weight without batteries48 kg147 kg147 kg225 kg225 kg
Noise<55dB<58dB<61dB<64dB
ColourBlack

Physical – L Model / External Battery Configuration

Specification10 kVA15 kVA20 kVA30 kVA40 kVA
Form FactorTower
Dimensions (W×D×H)250×868×900mm
UPS weight without external battery cabinet42 kg45 kg45 kg66 kg73 kg
Noise<55 dB<58 dB<61 dB<64 dB

Cable Sizing (minimum cross-section)

Cable10 kVA15 kVA20 kVA30 kVA40 kVA
AC Input4 mm²6 mm²8 mm²12 mm²16 mm²
AC Output4 mm²6 mm²8 mm²12 mm²16 mm²
DC Battery10 mm²16 mm²20 mm²35 mm²35 mm²
Ground4 mm²6 mm²8 mm²8 mm²10 mm²

Cable sizes are minimum reference values from the product specification. Final cable and breaker sizing must follow local electrical code, installation method, ambient temperature and project protection design.

InterfaceDetails
USBStandard USB for Muser4000 monitoring software (9600bps, 8N1)
RS-232DB9 Male serial (9600bps, 8N1) – Pin2=TXD, Pin3=RXD, Pin5=GND
RS-485RJ45 port for Modbus RTU and BMS / SCADA integration
Intelligent Slots2× slots – supports TM550 SNMP card and/or Relay card
Dry Contact Port4-pin: Battery Low, AC Fail, Turn Off UPS, Common GND
Parallel Ports2× parallel ports (ring topology, up to 4 units)
EPO / REPOEmergency Power Off / Remote Emergency Power Off
Events PortEvents logging connector
BAT_T PortRJ45 port for optional battery temperature sensor / dynamic charging
Maintenance BypassExternal maintenance bypass switch; internal / built-in bypass availability by model / configuration
Display7” colour touchscreen TFT HMI
SoftwareMuser4000 (USB/RS-232), SNMP_Management, SNMP_Protector
OptionalParallel kit, Relay card, TM550 SNMP card, Temperature sensor, External bypass PDU

Line Mode – Overload Capacity

Load LevelDurationAction
≤110%60 minutesSustained
≤125%10 minutesTransfer to bypass
≤150%1 minuteTransfer to bypass
≥150%ImmediateTransfer to bypass

Battery Mode – Overload Capacity

Load LevelDurationAction
≤110%10 minutesSustained on battery
≤125%1 minuteShutdown
≤150%5 secondsShutdown
≥150%ImmediateImmediate shutdown

Bypass Mode Note

ConditionBehaviour
Load >95%UPS remains on bypass and will not retransfer to inverter until load drops below 95%, according to bypass retransfer logic
ParameterSpecification
Operating Temperature0°C to 40°C (derate 12% per 5°C above 40°C, max 50°C)
Storage Temperature−25°C to 55°C
Humidity0–95% RH non-condensing
Altitude Derating1500m=100%, 2000m=95%, 2500m=90%, 3000m=85%, 3500m=80%, 4000m=75%
ClearanceMin 100cm front, 80cm rear for ventilation & maintenance
Safety StandardsIEC / EN 62040-1; LVD by series
EMC StandardsIEC / EN 62040-2; IEC 61000-4-2 / -3 / -4 / -5 / -6 / -8
CoolingForced air (fan)
InstallationIndoor use only
ApplicationsData centers, telecom, healthcare facility IT, industrial automation, transportation, energy and critical infrastructure

Downloads

TM33E 10-40 kVA Datasheet EN
TM33E 10-40 kVA User Manual EN
TM33E 10-40 kVA External Battery Cabinet Manual EN
TM550 SNMP Card Manual EN

Ideal For

TM33E 10–40 kVA is designed for three-phase critical loads from 10 to 40 kW at PF 1.0 – small and medium data centers, industrial control systems, telecom network rooms, healthcare facility IT and building infrastructure requiring protected 3-phase output.

Small and medium data center server racks backed up by ATENCO TM33E 3:3 online UPS

Small & Medium Data Centers

3:3 online UPS protection for server racks, PDUs, storage arrays, network cores, firewalls and high-density IT loads in small to medium data centers, server rooms and edge data center deployments.

Industrial automation, PLC and process control equipment backed up by ATENCO TM33E three-phase UPS

Industrial Automation & Process Control

Clean three-phase power for PLC panels, SCADA systems, industrial PCs, automation control cabinets, instrumentation and process-control equipment supplied from plant three-phase distribution.

Telecom switching rooms and network nodes backed up by ATENCO TM33E three-phase UPS

Telecom Switching & Network Nodes

Online three-phase UPS protection for telecom switching rooms, transmission equipment, access network nodes, microwave systems and core network infrastructure requiring stable 3-phase input / output power.

Healthcare facility IT, laboratory instruments and clinical monitoring infrastructure backed up by ATENCO TM33E three-phase UPS

Healthcare Facility IT & Laboratory Systems

Three-phase UPS protection for healthcare facility IT, laboratory instruments, clinical monitoring infrastructure, imaging support systems and technical rooms – subject to project electrical and certification requirements.

Security command and control rooms with NVR / VMS server clusters backed up by ATENCO TM33E three-phase UPS

Security Command & Control Rooms

Three-phase UPS support for centralized NVR / VMS server clusters, video-management workstations, access-control servers, monitoring walls and command-room infrastructure.

Commercial building network rooms, BMS and facility control infrastructure backed up by ATENCO TM33E three-phase UPS

Commercial Building Critical Infrastructure

Protected three-phase power for building network rooms, BMS panels, access-control systems, security servers, tenant IT infrastructure and facility control equipment in commercial or government buildings.

TM33E 10–40 kVA 3:3 UPS FAQ

Answers about TM33E three-phase input / three-phase output tower UPS architecture, 10–40 kVA capacity, PF 1.0 output, parallel operation, battery runtime and monitoring options.

What does TM33E mean?
TM33E is a 3:3 online three-phase tower UPS, meaning it accepts three-phase input and delivers protected three-phase output. The 10–40 kVA range is designed for data centers, industrial automation, telecom switching, healthcare facility IT and critical infrastructure projects with three-phase critical loads from 10 to 40 kW at PF 1.0.
What is the difference between TM33E 10–40 kVA and TM33E 50–200 kVA?
Both are TM33E three-phase tower UPS systems with PF 1.0 output. The 10–40 kVA range uses a compact platform with parallel operation up to 4 units for small to mid-size data centers, industrial sites and infrastructure projects. The 50–200 kVA range uses a higher-capacity platform with parallel operation up to 8 units for larger data centers and mission-critical infrastructure. Choose 10–40 kVA for projects up to 40 kW per unit; choose 50–200 kVA for larger single-unit ratings or larger parallel systems.
What is the difference between TM33E and TM31E?
TM33E is a three-phase input / three-phase output UPS, also called 3:3 UPS. TM31E is a three-phase input / single-phase output UPS, also called 3:1 UPS. Choose TM33E when the protected load requires 380 / 400 / 415 Vac three-phase output; choose TM31E when the site supply is three-phase but the protected loads require 220 / 230 / 240 Vac single-phase output.
What capacities are available for TM33E 10–40 kVA?
TM33E 10–40 kVA is available in 10, 15, 20, 30 and 40 kVA models. A 25 kVA model is not part of this range; the next standard rating above 20 kVA is 30 kVA. In PF 1.0 configuration, the UPS provides matching kW output capacity: 10, 15, 20, 30 and 40 kW. Internal-battery or external-battery configurations are available by model.
Can TM33E 10–40 kVA run on a generator?
Yes. TM33E supports a wide input voltage window – 208–478 Vac for 10–30 kVA models and 323–478 Vac for 40 kVA – with 45–55 Hz / 54–66 Hz auto-sensing input frequency. This makes it suitable for generator-backed sites and unstable utility conditions when the generator is properly sized. Input PF ≥0.99 and input THDi ≤3% help reduce upstream electrical stress.
Can TM33E 10–40 kVA be paralleled for redundancy?
Yes. Up to 4 TM33E 10–40 kVA units can be configured in parallel for capacity expansion or N+X redundancy, subject to model configuration and project design. Parallel cabling and commissioning must follow the installation procedure.
What battery runtime options are available for TM33E 10–40 kVA?
TM33E 10–40 kVA supports internal or external VRLA battery configurations by model. S models use an internal battery compartment by configuration, while L models use external TC-series battery cabinets for longer runtime. Battery quantity, DC bus voltage, cabinet model and runtime are selected according to UPS capacity, load level and target backup time. For exact battery counts and cabinet selection, ATENCO engineers size the battery system by project.
What monitoring options does TM33E 10–40 kVA support?
TM33E supports RS-232, USB, RS-485 / Modbus RTU, dry contact, EPO / REPO and dual intelligent slots by configuration. The optional TM550 SNMP card enables network monitoring, web access, event alerts and NMS / BMS integration. Relay card options are also available for dry-contact signalling. A 7-inch TFT touchscreen HMI provides on-unit monitoring and configuration. Muser4000 monitoring software is available for local monitoring.
Is TM33E 10–40 kVA transformer-based or transformer-less?
TM33E 10–40 kVA is transformer-less. For transformer-based, galvanic-isolation UPS configurations, use the TM33-ET range where the project requires an isolation transformer on the input, output or both.
Which applications is TM33E 10–40 kVA not recommended for?
TM33E is not the right choice when the protected load requires single-phase output; use TM31E 3:1 tower UPS or RM31E 3:1 rack UPS instead. It is also not the right choice when the site has only single-phase input; use TM11E or RM11E single-phase online UPS instead. For projects above 40 kVA per unit, use the TM33E 50–200 kVA range. Medical-grade or isolation-specific projects should be reviewed against the project's electrical, certification and isolation requirements.
TM33E 3:3 UPS Project Sizing

Size Your TM33E Three-Phase UPS Project

Share your three-phase load list, target backup time, redundancy plan, site voltage, generator details and monitoring requirements. ATENCO will recommend the suitable TM33E configuration – 10, 15, 20, 30 or 40 kVA, S or L variant – with TC-series battery cabinet, parallel and TM550 SNMP / RS-485 Modbus RTU / relay options matched to your project.

1

Send Project Requirements

Share three-phase load in kW / kVA, target runtime, redundancy requirement, site nominal voltage, generator details and monitoring preferences such as TM550 SNMP, RS-485 / Modbus RTU, relay, BMS or NMS integration.

2

Receive UPS Selection & Sizing

ATENCO engineers recommend the suitable TM33E configuration: 10 / 15 / 20 / 30 / 40 kVA, S or L variant, TC-series battery cabinet plan, parallel topology and matching TM550 SNMP, RS-485 / Modbus RTU or relay accessories.

Load & Runtime Sizing
Parallel / N+X Redundancy
S / L Variant & Battery Cabinet