Three Phase UPS Systems 10 kVA to 1.2 MW | ATENCO
Home / Products / Online Three Phase UPS

Three Phase UPS Systems
10 kVA to 1.2 MW

Online double-conversion three-phase UPS systems from 10 kVA to 1.2 MW for data centers, industrial automation, telecom, healthcare and critical infrastructure projects. ATENCO offers 3:1, 3:3, tower, rack, transformer-based and modular UPS configurations with external battery runtime, SNMP / Modbus monitoring, parallel redundancy and PF 1.0 options available by series.

10 kVA to 1.2 MW Online UPS 3:1 / 3:3 Three-Phase Systems Tower / Rack / Transformer / Modular Runtime / Monitoring / Redundancy Options

Three Phase UPS Comparison Table

Compare ATENCO 3:1, 3:3, rack-mounted, transformer-based and modular online UPS systems by capacity, phase, power factor, redundancy and application.

Series Architecture Capacity Phase PF Best For Redundancy / Runtime Efficiency
TM31E
TM31E
3:1 online tower UPS 10–20 kVA 3:1 0.9 Three-phase input sites with single-phase critical loads External battery runtime by configuration Up to 94% Details →
RM31E
RM31E
3:1 rack/tower online UPS 6–10 kVA 3:1 0.9 Rack-based telecom, IT and control-room loads External / hot-swap battery options by model Up to 93.5% Details →
TM33E
TM33E 10–40 kVA
3:3 online tower UPS 10–40 kVA 3:3 1.0 Small / medium 3-phase data center, facility and industrial loads Parallel redundancy and external battery runtime by configuration Up to 94.5% Details →
TM33E 50-200
TM33E 50–200 kVA
3:3 standalone online UPS, 3-Level IGBT 50–200 kVA 3:3 1.0 Medium / large data center, healthcare, telecom and industrial loads Parallel up to 8 units and LBS by configuration; VRLA / lithium battery support by project Up to 95.5% Details →
RM33E
RM33E
3:3 rack-mounted online UPS 10–50 kVA 3:3 1.0 Edge data centers, server racks and compact 3-phase IT power Parallel / LBS options by model and configuration Up to 95.5% Details →
TM66E
TM66E NEW
Modular online UPS platform 40 kVA to 1.2 MW 3:3 1.0 Scalable data center and large industrial N+X systems Hot-swappable modules, N+X redundancy and external battery runtime by configuration Up to 96.5% Details →
TM33-ET
TM33-ET
Transformer-based online UPS 10–800 kVA 3:3 0.9 Industrial transformer-based UPS and robust power-conditioning projects Parallel / LBS / generator-compatible configuration by project Up to 94% Details →

30+ Years

UPS industry experience

50+ Countries

Distributor network worldwide

0 ms Online Transfer

Zero-transfer online double-conversion

CE / IEC 62040

Safety & EMC standards by series

Three-Phase UPS Project Sizing

Size the Right Three-Phase UPS
System for Your Project

Share your load list, redundancy plan, site voltage, input/output phase, backup-time target, battery preference, installation space and monitoring requirements. ATENCO will recommend the suitable standalone, rack, transformer-based or modular three-phase UPS configuration from 10 kVA to 1.2 MW.

1

Send Project Requirements

Share your single-line diagram or load list, target backup time, redundancy plan (N, N+1, N+X), site voltage, ambient conditions and installation constraints.

2

Receive UPS Selection & Sizing

ATENCO engineers respond with the recommended TM31E, RM31E, TM33E, TM33-ET or TM66E configuration, battery / runtime options and monitoring setup matched to your project.

Load & Runtime Sizing
N / N+1 / N+X Redundancy
Battery & Monitoring Options